Installation, Equipment, Air control – Ransburg Turbodisk 2 Assembly 78715 User Manual

Page 16: Mounting, Interlocks

Advertising
background image

Turbodisk 2 - Installation

INSTALLATION

EQUIPMENT

This system should be installed by, or under the

supervision of an Ransburg representative. Should the

need arise to replace any component assembly within

the system, contact your Ransburg representative.

This manual concerns normal operation, maintenance,

and service of the specified applicator assemblies. The

air and fluid connections vary with different models

and installations. This manual deals primarily with

those at, or within the assembly.

12

AIR CONTROL

-REFER TO FIGURE 2

Air control of the applicator is from a standard

Ransburg air logic panel, which includes two filters

(one 40 micron filter located at the air logic station

and one 5 micron filter located at the inlet of the in-

line air heater panel). Clean, dry factory air must be

provided to the inlet filter of the air logic station via

a minimum 1/4-inch I.D. pipe and to the inlet filter of

the heater panel via a minimum 3/4-inch I.D. pipe.

MOUNTING

-REFER TO FIGURE 17 & 24

The Turbodisk 2 assembly is mounted on the

reciprocator using (4) 5/16-18 screws provided on

the ram flange. Loosening (2) 1/4-20 screws on the

same ram flange will allow the assembly to rotate.

Position the Turbodisk 2 assembly so that the strain

relief boot is positioned toward the incoming fluid

and air lines and retighten.

Remove lower fairing by releasing the (4) quick release

draw latches. Thread all the required air, high voltage,

fiber optic, and fluid service lines through the strain

relief boot. The strain relief boot may have to be cut

larger in order to feed all the lines through. Refer to the

78718 assembly/schematic diagram for connection

reference to upper bulkhead plate.

Reinstall lower fairing. Install conical disk and torque

to 50-60 lb

in.

INTERLOCKS

Flow of coating material should be locked out unless

all of the following conditions are met:

1.

Booth exhaust is turned on.

2.

The turbine is spinning.

3.

High voltage is on or in the bypass mode.

LN-9240-02.1