4 test condition – Acer P1166 User Manual

Page 68

Advertising
background image

Confidential

4-2

P1166 / P1266 / P1266i / P1166P / P1266P

4-4 Test Condition

- Circumstance brightness: Dark room less than 5.0 lux.
- Inspection distance: 1.8 M~2.5 M functional inspection.
- Screen size: 60 inches diagonal
- After repairing each

P1166 / P1266 / P1266i / P1166P / P1266P

, the unit should be run-in

(refer to the table below)

Symptom

Run-in Time

Normal repair

2 hours

NFF

4 hours

Auto shut down

6 hours

- Get into Burn-In Mode

* Cycle setting is based on the defect symptoms. ie: If it is NFF, the run-in time is 4 hours. You have

to set the lamp on for 50 min. and lamp off for 10 min for 4 cycles.

Press power > left > left > Menu
Choose Burn-In Test > enter
Lamp On (Min)

Press right key to adjust the time (50)

Lamp Off (Min)

Press right key to adjust the time (10)

Set burn in cycle

Press right key to adjust the cycle

After setting up the time, choose Burn-In mode and hit enter

Screen Defects (While replacing DMD Chip, DMD BD and MB)