10 optical performance measure – Acer P1166 User Manual

Page 76

Advertising
background image

Confidential

4-10

P1166 / P1266 / P1266i / P1166P / P1266P

4-10 Optical Performance Measure

Inspection Condition
- Environment luminance: 5 Lux
- Product must be warmed up for 3 minutes
- Distances from the screen: 1.95 M
- Screen Size: 60 inches diagonal

1. Test equipment

Procedure

- Get into service mode: Press "Power→Left→

Left→Menu".

- Select "RD menu"

"RD menu"

RD menu""

- Select "Spoke test"

"Spoke test"

Spoke test""

2. Brightness

Procedure

- Full white pattern

- Use CL100 to measure brightness values of

P1~P9.

- Follow the brightness formula to calculate

brightness values.

☼ Brightness Formula

Avg. (P1~ P9) x 1.1m

2

Criteria

�� 1100 lumens (for P1166 / P1266)

�� 1100 lumens (for P1166 / P1266)

1200 lumens (for P1266i / P1166P / P1266P)

3. Full On/Full Off Contrast

Procedure

- Full white pattern & full black pattern

- Use CL100 to measure brightness values of full

white pattern P5 & full black pattern B5 ( see

image: full white)

- Follow Contrast formula to calculate contrast

values.

☼ Contrast Formula

P5/B5

Full white pattern

Advertising