Note: P5=center of white image

B5=center of black image.

Criteria

�� 1400: 1 (for P1166 / P1266)

�� 1400: 1 (for P1166 / P1266)

1400: 1 (for P1166 / P1266)

(for P1166 / P1266)

1900: 1 (for P1266i / P1166P / P1266P)

4. Uniformity

Procedure

- Full white pattern

- Use CL100 to measure brightness values of P1~P9

(see image: full white).

- Follow the Uniformity formula to calculate

average values.

☼ Uniformity Formula

ANSI Uniformity = Avg. (P1, P3, P7, P9) / P5 x 100�

P5 x 100�

Criteria

�� 65�


4-11 Others

1. Functional Inspection

Keypad button

- All keypad buttons must operate smoothly.

General

- All OSD functions must be checked for functionality.

When OSD menu is displayed, there shall be no vis-

ible peaking, ringing, streaking, or smearing artifacts

on the screen.

Factory Default

- The factory settings (with appropriate centring, size,

geometry distortion, etc.) shall be displayed upon

“Recall” is selected from OSD.

Display Size

- All preset modes shall expand to full screen size us-

ing OSD

Horizontal and Vertical Size controls

Display Data Channel - The purpose of the DDC test is to verify the DDC1/