4operating instructions, Recovery procedure warning – Robinair 25200B Refrigerant Recovery Unit User Manual

Page 6

Advertising
background image

4

operating Instructions

reCovery ProCedUre

WarnInG

To prevent personal injury,
Read and follow all warnings at the beginning of this manual

before operating the unit. Wear safety goggles when working with

refrigerants. Use only authorized refillable refrigerant tanks.
Disconnect hoses using extreme caution. All hoses may contain

refrigerant under pressure.

1. Connect hoses as described in the Setup Instructions.
2. Open the LIQUID and VAPOR valves on the recovery tank. Open the ball

valves on all four hoses.

NOTE: To prevent overfilling, monitor the tank capacity/weight during recovery.

During liquid recovery, refrigerant transfers rapidly. Monitor tank weight using the

appropriate weight scale.
3. Look at the system pressure gauge on the unit to confirm there is refrigerant

pressure in the system. If there is no pressure, there is no refrigerant to be

recovered.

NOTE: By taking the ambient temperature and using a pressure/temperature chart,

you can use this pressure to determine the type of refrigerant in the system.
4. Turn the switch to RECOVER. The light on the switch illuminates and you

will hear the compressor start.

A float chamber monitors the refrigerant being recovered and automatically adjusts

the unit to handle either liquid or vapor refrigerant. This provides for the most

efficient recovery. The amber light on the control panel indicates when liquid is

entering the unit.
5. The blue gauge labeled SYSTEM PRESSURE shows the current system

pressure throughout the recovery process. When the system pressure reaches

an adequate vacuum level, turn the RECOVERY switch OFF.

The recovery process is complete, but the unit must be cleared before disconnecting

all hoses. (Refer to the Self-Clearing Procedure.)

Refrigerants

30 lb. Tank

50 lb. Tank

R-12

22 lbs.

40 lbs.

R-22

22 lbs.

40 lbs.

R-134a

22 lbs.

41 lbs.

R-407C

21 lbs.

39 lbs.

R-410A

19 lbs.

36 lbs.

TANk CAPACITy CHART

Advertising