TEL OUT
TEL OUT

SIM

Cable Management Slots

Mounting Holes

SIM Card Slot

Power

Backup Battery ON/OFF

9

• Incoming Calls: During an incoming call event, the SM-GSMdialer will
click (relay sound) once for every ring and the ”Call Pick Up” red LED will
flash until the phone is answered or the call is no longer coming through.

Low Power
During power failure, the Low Power LED will stay “Solid Red” only
when the batteries have less than 7V of charge remaining indicating
that the internal backup batteries need to be charged. When the Low
Power red LED comes on the GSM dialer will continue to functions
normal for 20 minutes from the time the LED light comes on.

SIM Problem
The SIM Problem red LED stays ON only if there is no SIM card inserted
into the SM-GSMdialer, inserted card is not active, or an error occurs
during normal operation. If an error should occur during normal
operation, please power cycle the unit by switching it to the off
position and disconnecting it from the power outlet.

NOTE: Please contact your SIM card provider if the error persists.

Back Panel

GSM Antenna

TEL OUT to Alarm Host

TEL OUT to Phone/
Alarm Host