Programming

101

NXD-500i 5" Wall/Flush Mount Touch Panel with Intercom

"^" Button Commands (Cont.)

^ENA

Enable or
disable buttons
with a set
variable text
range.

Syntax:

"'^ENA-<vt addr range>,<command value>'"

Variable:

variable text address range = 1 - 4000.
command value = (0= disable, 1= enable)

Example:

SEND_COMMAND Panel,"'^ENA-500.504&510.515,0'"

Disables button pushes on buttons with variable text range 500-504 & 510-515.

^FON

Set a font to a
specific Font ID
value for those
buttons with a
defined address
range.

Font ID numbers are generated by the TPDesign4 programmers report.
Syntax:

"'^FON-<vt addr range>,<button states range>,<font value>'"

Variable:

variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
font value = Range = 1 - XXX. Refer to theDefault Font Styles and ID Numbers table on
page 85.

Example:

SEND_COMMAND Panel,"'^FON-500.504&510.515,1&2,4'"

Sets the font size to font ID #4 for the On and Off states of buttons with the variable text
range of 500-504 & 510-515.

The Font ID is generated by TPD4 and is located in TPD4 through the Main menu.
Panel > Generate Programmer's Report >Text Only Format >Readme.txt.

"^" Button Commands (Cont.)

^GDI

Change the
bargraph drag
increment.

Syntax:

"'^GDI-<vt addr range>,<bargraph drag increment>'"

Variable:

variable text address range = 1 - 4000.
bargraph drag increment = The default drag increment is 256.

Example:

SEND_COMMAND Panel,"'^GDI-7,128'"

Sets the bargraph with variable text 7 to a drag increment of 128.