AMX Modero NXD-500i User Manual

Page 68

Advertising
background image

Setup Pages and Descriptions

62

NXD-500i 5" Wall/Flush Mount Touch Panel with Intercom

G4 Web Control Page

The G4 Web Control page (FIG. 47) centers around enabling and disabling both the display and control
of your panel (via the web). An external PC running a VNC client, installed during the initial
communication to the G4 panel, makes this possible.

Each panel supports the open standard Virtual Network Computing (VNC) interface. These panels
contain a VNC server that allows them to accept a connection from any other device running a VNC
client. Once a connection is established to that target device, the client can control the touch panel
remotely. The elements of the G4 Web Control page are as follows:

FIG. 47

G4 Web Control page

G4 Web Control Page Elements

Back:

Saves the changes and returns to the previously active touch panel page.

Connection Status icon:

This visual display of the connection status allows the user to have a current
visual update of the panel’s connection status regardless of what page is
currently active.
• A Lock only appears on the icon if the panel has established a connection

with a currently secured target Master (requiring a username and password).

G4 Web Control Settings:

Sets the IP communication values for the touch panel and contains:

Enable/Enabled

• The Enable/Enabled button allows you to toggle between the two G4

activation settings:
- Enable - deactivates the G4 Web Control feature on the panel.
- Enabled - activates the G4 Web Control feature on the panel and allows
an external PC running a VNC client to access the panel after the
remaining fields are configured.

Network Interface Select

Displays the detected method of communication to the web:
Wired is used when a direct Ethernet connection is being used for

communication to the web. This is a default setting.

Web Control Name

Allows entry of a unique alphanumeric string used as the display name of the
panel within the Manage WebControl Connections window of the new NetLinx
Security browser window.
• This Web Control tab displays a G4 icon alongside the link to the Web Control

Name given to this panel (FIG. 48).

Web Control Password

Allows entry of the G4 Authentication session password associated for VNC
web access of this panel.

Web Control Port

Allows entry of the VNC Web Server’s port value.
• Default value is 5900.

Maximum Number of
Connections

This read-only field displays the maximum number of users that can be
simultaneously connected to the target panel via the Web.
• Default value is 1.