Sensor setup – AMX Modero NXD-500i User Manual

Page 74

Advertising
background image

Setup Pages and Descriptions

68

NXD-500i 5" Wall/Flush Mount Touch Panel with Intercom

Sensor Setup

The Sensor Setup page (FIG. 51) allows adjustment of the Light and Motion Sensor parameters on a
Modero touch panel.

The elements of the Sensor Setup page are described in the table below:

FIG. 51

Sensor Setup page

Sensor Setup Page Elements

Back:

Saves the changes and returns you to the previously active touch panel page.

Connection Status icon:

This visual display of the connection status allows the user to have a current
visual update of the panel’s connection status regardless of the page that is
currently active.
• A Lock only appears on the icon if the panel has established a connection

with a currently secured target Master requiring a username and password.

Light:

The Light bargraph displays a vertical bargraph indicating the light level
detected by the on-board photo-sensor.

Light Sensor:

Allows the user to review the Modero panel light sensor port and channel
settings:
• The Sensor Level field indicates the level used to report the light sensor level

back to the NetLinx Master (set in TPD4) (read-only).

• The Sensor Level Port field indicates the port used to report the light sensor

level back to the NetLinx Master (set in TPD4) (read-only).

• The Sensor Channel field indicates the level used to report the sensor

channel back to the NetLinx Master (set in TPD4). It is On when below the
Light Sensor threshold level (read-only).

• The Sensor Channel Port field indicates the port used to report the sensor

channel back to the NetLinx Master (set in TPD4) (read-only).

Motion Sensor:

Provides the following fields:
• The Motion Detection field displays a reactive button that changes color

(illuminates) when motion is detected by the Modero panel’s front motion
sensor.

• The Motion Sensor Port field indicates the port used to report the motion

sensor channel back to the NetLinx Master (set in TPD4) (read-only).

• The Motion Sensor Channel field indicates the channel used to report the

motion sensor channel back to the NetLinx Master (set in TPD4) (read-only).

Advertising