STRIDER ESSENTIAL SERIES

5.0 REGULATORY COMPLIANCE

5.1 SAFETY REQUIREMENTS

-IEC 950

-TUV EN 60950

-NEMKO + CB REPOR

-CUL

5.2 DIELECTRIC STRENGTH

Primary to Frame Ground: 1800 Vac for 1 sec.

Primary to Secondary: 1800 Vac for 1 sec.

5.3 INSULATION RESISTANCE

Primary to Secondary: 20 Meg. ohms minimum.

Primary to FRAME GROUND: 20 Meg. ohms minimum.

5.4 GROUND LEAKAGE CURRENT

The power supply ground leakage current shall be less than 3.5mA.

5.5 EMISSION REQUIREMENTS

The power supply shall comply with CISPR 22, Class B, for both conducted

and radiated emissions with a 4dB margin..

6.0 OTHER REQUIREMENTS

6.1 INPUT CONNECTIONS

Refer to Mechanical Specifications for placement.The AC mains input are

through a three-circuit IEC type connector mounted on the rear of the

power supply chassis.

6.2 RELIABILITY

The power supply reliability, when calculated by “Bellcore” latest revision are

exceed 100,000 hours with all output at maximum load and an ambient

temperature of 25℃.

The special requirement is for cooling fan that MTTF be guarantee

over 20,000 hours at 40℃ ambient temperature.