STRIDER ESSENTIAL SERIES

06

Output Voltage

Protecting trigger condition

5V

< 45A

12V

< 62A

3.3V

< 60A

3.3 OUTPUT VOLTAGE HOLD-UP TIME

16.0 mS minimum : at 115V / 60 Hz. (80%LOAD)

3.4 OPERATION AT NO LOAD

The power supply shall be capable of being operated with no load on any or all outputs

without damage. For no load on +3.3V & +5V, the output shall not exceed +4.3V & +6.5Vdc

and the power supply may shutdown and require by remote-control or remove AC power restart.

3.5 PROTECTION

3.5.1 OVER-VOLTAGE PROTECTION

In the event of an over-voltage condition on +3.3 & +5Vdc &+12V the power supply shall

shutdown and require remote control or remove the AC mains input to reset the system.

+5V : 6.5V (maximum)

+3.3V : 4.3V (maximum)

+12V : 15.5V (maximum)

3.5.2 OVER- CURRENT PROTECTION

There shall be protection from an output over-current event. The PSU may shutdown

form such an event and require power-on restart. The overload currents should be

ramped at a minimum rate of 10 A/s starting from full load.

SST-ST70F-ESG:

Output Voltage

Protecting trigger condition

5V

< 45A

12V

< 52A

3.3V

< 60A

SST-ST60F-ESG:

Output Voltage

Protecting trigger condition

5V

< 45A

12V

< 46A

3.3V

< 60A

SST-ST50F-ESG:

OVER-CURRENT TEST VALUES: