Strider essential series, Load regulation characteristics, Sst-st50f-esg – SilverStone ST50F-ESG User Manual

Page 5

Advertising
background image

STRIDER ESSENTIAL SERIES

04

X

X

1.5A

24A

1.5A

3A

3.6A

10A

13.41A

14A

LOAD CONDITION

NO

OUTPUT LOAD

+3.3V

+5V

+12V

-12V

+5Vsb

COND.1

1

COND.2

2

COND.3

3

COND.4

4

COND.5

5

COND.6

6

COND.7

7

COND.8

COND.9

COND.10

8

9

10

X

X

1A

1A

24A

6A

3.6A

10A

13.41A

14A

X

X

1A

8A

8A

46A

2.6A

22A

44A

39.39A

X

X

0A

0A

0A

0A

0.3A

0.25A

0.26A

0.3A

3.5A

3A

0.1A

0.1A

0.1A

0.1A

3A

1A

2.57A

3A

LOAD REGULATION CHARACTERISTICS

(3) Voltages and ripple are measured at the load side of mating connectors with a 0.1uF

monolithic ceramic capacitor paralleled by a 10uF electrolytic capacitor across the

measuring terminals.

SST-ST50F-ESG:

Cond. 10 only at 115Vac/60Hz and less then 1 S
Cond. 1 only at 115Vac/60Hz and less then 100 mS

+5Vsb peak current is 3.5A(less then 0.5S)

MINIMUM

LOAD

NORMAL

LOAD

MAXIMUM

LOAD

LOAD

REG

LINE

REG

RIPPLE & NOISE

+3.3V

+5V

+12V

-12V

+5Vsb

0.2A

1A

1A

0A

0A

10A

9A

22A

0.25A

1A

24A

20A

39A

0.3A

3A

±5%

±5%

±5%

±10%

±5%

±1%

±1%

±1%

±2%

±1%

50mV P-P

50mV P-P

120mV P-P

120mV P-P

50mV P-P

Advertising
This manual is related to the following products: