background image

05

X

X

1.5A

24A

1.5A

3A

3.6A

10A

13.25A

12A

LOAD CONDITION

NO

OUTPUT LOAD

+3.3V

+5V

+12V

-12V

+5Vsb

COND.1

1

COND.2

2

COND.3

3

COND.4

4

COND.5

5

COND.6

6

COND.7

7

COND.8

COND.9

COND.10

8

9

10

X

X

1A

1A

20A

6A

3.6A

9A

11.04A

12A

X

X

1A

7A

7A

39A

2.6A

20A

36A

32.15A

X

X

0A

0A

0A

0A

0.3A

0.25A

0.26A

0.3A

3.5A

3A

0.1A

0.1A

0.1A

0.1A

3A

1A

2.47A

3A

LOAD REGULATION CHARACTERISTICS

Cond. 10 only at 115Vac/60Hz and less then 1 S
Cond. 1 only at 115Vac/60Hz and less then 100 mS

(1) +3.3V & +5V total output not exceed 120W.

When +5V is load to 20A, the +3.3V maximum load is 7.5A.

When +3.3V is load to 24A, the +5V maximum load is 9A..

(2) All outputs shall be safety-isolated from the AC mains and share a common

return. This common return must be connected to supply chassis.

(3) Voltages and ripple are measured at the load side of mating connectors

with a 0.1uF monolithic ceramic capacitor paralleled by a 10uF electrolytic

capacitor across the measuring terminals.

3.2 REMOTE ON/OFF CONTROL

The power supply shall accept a logic open collector level which will disable/ enable all

the output voltage (exclude + 5V standby).

As logic level is low, outputs voltage were enabled.

As logic level is high, outputs voltage were disabled.

Note: 1. Logic high level: 2.0-5.25V while sourcing 0.2mA maximum.

2. Logic low level: 0-0.5V while sinking 1.6mA maximum.