7.0 Troubleshooting



Read and comply with instructions in this manual and use the hoist properly.

Checking the sounds from the hoist in operation is a critical inspection. Note hoist sounds during operation.

If a defect is found in the hoist, stop using it immediately and check the cause of the defect.

Only Trained and competent personnel should inspect and repair the hoist.

Table 7-1 Troubleshooting Guide

Note on proper operation:

When lifting, the hoist should make clicking sounds when moving the hand wheel.

When lowering, the hoist should not make clicking sounds when moving the hand wheel.

Symptom

Cause

Remedy

Hoist will not lift

Slight clicking

Improper assembly of ratchet disc, disc
installed backwards, and making incorrect
contact with the pawl.

Reassemble the pawl and ratchet disc
properly. Ensure that clicking sounds are
heard before reuse.

Hoist will not lift

Not Clicking

Pawl not engaging ratchet disc:

Dirt or corrosion between pawl and pawl
shaft.

Clean and lubricate pawl and pawl shaft.

Pawl shaft

Pawl

Faulty pawl spring

Replace pawl spring

Loose selector pawl spring

Perform hoist maintenance.

Hoist will not lift

Hand wheel will not
operate

Gear #2 improperly timed

Reassemble gears properly and ensure
smooth operation before reuse.



Ensure the

„0‟ & “V”

marks of gear #2 are aligned properly, as
shown.