Vertical System: Digital Channels (54621D, 54622D, 54641D, and 54642D only)

Number of Channels

16 Digital – labeled D15 - D0

Threshold Groupings

Pod 1: D7 - D0
Pod 2: D15 - D8

Threshold Selections

TTL, CMOS, ECL, user-definable (selectable by pod)

User-Defined Threshold Range

±8.0 V in 10 mV increments

Maximum Input Voltage

±40 V peak CAT I

Threshold Accuracy*

±(100 mV + 3% of threshold setting)

Input Dynamic Range

±10 V about threshold

Minimum Input Voltage Swing

500 mV peak-to-peak

Input Capacitance

~ 8 pF

Input Resistance

100 k

±2% at probe tip

Channel-to-Channel Skew

2 ns typical, 3 ns maximum

Horizontal

Range

54621A/D, 54622A/D, 54624A: 5 ns/div to 50 s/div
54641A/D, 54642A/D: 1 ns/div to 50 s/div

Resolution

54621A/D, 54622A/D, 54624A: 25 ps
54641A/D, 54642A/D: 2.5 ps

Vernier

1-2-5 increments when off, ~25 minor increments between major settings when on

Reference Positions

Left, Center, Right

Delay Range

54621A/D, 54622A/D, 54624A:

Pre-trigger (negative delay): Greater of 1 screen width or 10 ms
Post-trigger (positive delay): 500 seconds

54641A/D, 54642A/D:

Pre-trigger (negative delay): Greater of 1 screen width or 1 ms
Post-trigger (positive delay): 500 seconds

Analog Delta-t Accuracy

54621A/D, 54622A/D, 54624A:

Same Channel*: ±0.01% reading ±0.1% screen width ±40 ps
Channel-to-Channel: ±0.01% reading ±0.1% screen width ±80 ps

54641A/D, 54642A/D:

Same Channel*: ±0.005% reading ±0.1% screen width ±20 ps
Channel-to-Channel: ±0.005% reading ±0.1% screen width ±40 ps

Same Channel Example (54641A/D, 54642A/D):

for signal with pulse width of 10 µs, scope set to 5 µs/div (50 µs screen width),
delta-t accuracy = ±{.005%(10 µs) + 0.1%(50 µs) + 20 ps} = 50.52 ns

* Denotes Warranted Specifications, all others are typical. Specifications are valid after a 30-minute warm-up period and ±10 °C from firmware calibration temperature.

Advertising