16

3.6.2



Supply line inside diameter - Pipes and hoses should be sized to accommodate

the hoist’s airflow requirements. The inside diameter for the pipe section feeding the hoist should be
12.7mm (½”) or larger and for air supply hose the inside diameter should be 9.5mm (3/8”) inch or larger.

3.6.3



Hoses - The connection from the air supply system piping to the hoist must be

made with a flexible pressure hose. Due to normal line losses in air supply lines:

Do not use hose smaller than specified in Section 3.6.2, and

Limit the length of the hose to that specified in Figure 3-3.

If your application exceeds these requirements consult factory.

Figure 3-3 Typical Arrangements of Filter, Regulator and Lubricator and

Maximum Air Supply Hose Lengths

3.6.4



Fittings - Important considerations regarding fittings in the hoist’s air supply

include:

When connecting air supply components, remove all dirt or debris from the connecting surfaces of
the hoses, pipes, fittings, or threaded fasteners to prevent contaminants from entering the hoist.

Keep airflow restrictions such as quick disconnect fittings, bends, elbows, and adapters to a
minimum.

3.6.5



Before connecting the hoist to its air supply line, perform the proper draining and

purging procedures to prevent contaminants or moisture from entering the hoist.

3.7

Mounting Location

3.7.1



Prior to mounting the hoist ensure that the suspension and it supporting structure

are adequate to support the hoist and its loads. If necessary consult a professional that is qualified to
evaluate the adequacy of the suspension location and its supporting structure.

3.7.2



See Section 7.6 for outdoor installation considerations.