Harrington Hoists and Cranes AHM Hoist User Manual

Page 42

Advertising
background image

42

Figure 7-7 Load Sheave Inspection

7.5

Storage

7.5.1

Whenever the hoist is to be placed into storage, place extra lubricating oil into the air inlet opening and
circulate the air motor before plugging the inlet. Make certain that no debris, dirt or moisture is allowed
to enter the air hoist through air inlet opening during preparations for storage.

7.5.2

The storage location should be clean and dry.

7.6

Outdoor Installation

7.6.1

For hoist installations that are outdoors, the hoist should be covered when not in use.

7.6.2

In order to prevent internal corrosion from occurring, the hoist must be operated using proper quality air
at least once per week by raising and lowering the hoist one full cycle. Note: the possibility of corrosion
in the valve section of the hoist increases for areas where salt air and high humidity are present. For
such situations you may need to operate your hoist more often than once per week.