Position no.1 position no.2, 5) tension operation „ image diagram – IAI America ERC3 User Manual

Page 191

Advertising
background image

Chapter 4 Operation

4.2 Operation in Positioner Mode

4.2.2 Operation in Positioner Mode 1

181

(5) Tension Operation

„

Image diagram

Position No.1

Position No.2

No.

Position

[mm]

Velocity

[mm/s]

Accele-

ration

[G]

Decele-

ration

[G]

Pressing

[%]

Thresh-

old

[%]

Positioning

width
[mm]

Zone+

[mm]

Zone-

[mm]

Acceleration/

Deceleration

mode

Incre-

mental

Transported

load

Stop

mode

0

1

100.00

250.00

0.20

0.20

0

0

0.10

0.00

0.00

0

0

0

0

2

80.00

250.00

0.20

0.20

50

0

–50.00

0.00

0.00

0

0

0

0

3

CSTR : Start position

„

Control method

The method of controlling the tension operation is the same as that described in (4) Pressing

operation. The control method is explained below by using the sample position table shown

above.

1) Position No.2 indicates the settings of tension operation. The settings of “Position” and

“Positioning width” show the tension start position and the tension quantity, respectively.

Attach – (minus sign) to the tension quantity. Specify the upper limit of the torque required

for tension in percent (limited current value) in “Pressing”. The speed, acceleration, and

deceleration are the conditions of positioning to the coordinate value (80mm) set in

“Position”.

2) Position No.1 indicates the tension start preparation position. Specify a value larger than

the coordinate value at which the tension provided by position No.2 ends (80 – 50 = 30mm)

in “Position”.

3) First define the positioning in position No.1. Next, the operation in position No.2 moves the

actuator to the position of 80mm at the setting speed and rating torque and change to the

tension operation. The actuator moves by 50mm in the negative direction in the tension

operation. The upper limit of the tensile force is the torque set in percent.

4) In the similar way as pressing, the positioning complete signal is output when the shaft is

stopped by tension (pressing complete). If the actuator cannot be stopped during

movement within the setting positioning width (miss-pressing), it moves by the setting

distance to stop but PEND is not turned ON.

CSTR

Tension Operation

CSTR

Approach Operation

Tension Operation

Tension start position

80mm

Temsion end position

80 – 50 = 30mm

Advertising