Example of calculation and operation availability judgment

As an example of a calculation, let's see if the continuous operation is available under the following
operational conditions.

Pressing after 100mm moving forward and standby after 100mm backwards
Refer to Graph 6 for the operation pattern.
*1

The current value when stopped is as shown in the following parameter.
Ɣ PCON Controller: No.12 Current Limit Value at Positioning Stop (60% when delivered)

1) Condition 1

Confirmation of pressing duration

According to Table 1, the maximum pressing duration at 70% of the pressing command value is 600s.
On the other hand, the operation pattern is 60s. Thus, the pressing duration should be okay.

2) Condition 2

Confirmation of continuous operation torque.

Figure out the continuous operation torque using Formula 1 that is for continuous torque calculation.

• • • (Formula 1)

T1a = T1d = T2a = T2d = 0.93N•

P 6SHHGPPVHF· PPVHFĺ5HDGWKHWRUTXHDW

100mm/sec from Graph 4)

T1f = T2f = 0.42N•

P 6SHHGPPVHFĺ5HDGWKHWRUTXHIURP*UDSK

To = 2.43N•

P

ĺ5HDGWRUTXHIURP*UDSK

Tw = 1.39N•

P

ĺ5HDGWRUTXHIURP*UDSK

t1a = t1d = t2a = t2d = 0.2s. t1f = t2f = 0.9s. To = 60s. Tw = 36s.
The continuous operation torque with the operation pattern above is:

It can be defined as okay since the continuous operation torque is 2.08N•m or less.

Graph 6: Operational Pattern

Used Model: RCP2-RA8 Lead 10

Speed: 200mm/sec

Acceleration/Deceleration: 1.96m/s

2

(0.2G)

Operation Distance: 100mm

Pressing Command Value: 70% (1000N)

Pressing Duration: 60sec

Stop Current Limit Value: 40%

*1

Standby Duration: 36sec