5. Installation

5.6

Suction for the Cleanroom Type

IS actuators of cleanroom specification with protective stainless sheet can demonstrate their designed
cleanliness of cleanroom class 10 (0.3

Pm) when air is suctioned from the suction joint. The table below

lists reference suctioning rates for each model at different rated speeds.

5.6.1

Reference Suctioning Rates

Model

Lead

Suctioning rate (N/min)

Pressure (mmAq)

4 10 -3
8 20 -6

IS(P)D(A)CR-S

16 30 -13

5 15 -4

IS(P)D(A)CR-M

10 30 -12

IS(P)D(A)CR-M(X)

20

70

-40

IS(P)D(A)CR-L

10

30

-10

IS(P)D(A)CR-L(X)

20

90

-60

10 40 -60
20 60 -170

IS(P)D(A)CR-W(X)-600

40 120 -520
25 60 -170

IS(P)D(A)CR-W(X)-750

50 120 -520

x Prepare an air tube and connect it to the suctioning port, or the quick joint of ‡12 in external diameter

provided on a side face of the actuator, and use a vacuum pump, blower, ejector, etc., to suction air at
an appropriate flow rate as specified above.

x If suctioning equipment is available, check its capacity. If no suctioning equipment is available, select a

vacuum pump, blower or other appropriate suctioning equipment by referring to the values listed above.