2. X-SEL-J/K/P/Q/JX/KX/PX/QX

I/O parameters for X-SEL J/K types

No. Parameter

name

Default value

(reference)

Input

range

Setting

Remarks

1

I/O port assignment type

0

0 ~ 20

0

0: Fixed assignment
1: Automatic assignment (Priority:

Assigned from slot 1)

* Ports are assigned consecutively only

for slots where a board is physically
installed, starting from slot 1, for safety
reasons.

2

Input port start number for standard I/O
based on fixed assignment (I/O1)

000

-1 ~ 599

000

0 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)

3

Output port start number for standard
I/O based on fixed assignment (I/O1)

300

-1 ~ 599

300

300 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)

4

Input port start number for expansion
I/O1 based on fixed assignment (I/O2)

-1

-1 ~ 599

256

0 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)
(Slot immediately next to the standard I/O
slot)

5

Output port start number for expansion
I/O1 based on fixed assignment (I/O2)

-1

-1 ~ 599

556

300 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)

6

Input port start number for expansion
I/O2 based on fixed assignment (I/O3)

-1

-1 ~ 599

-1

0 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)

7

Output port start number for expansion
I/O2 based on fixed assignment (I/O3)

-1

-1 ~ 599

-1

300 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)

8

Input port start number for expansion
I/O3 based on fixed assignment (I/O4)

-1

-1 ~ 599

-1

0 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)

9

Output port start number for expansion
I/O3 based on fixed assignment (I/O4)

-1

-1 ~ 599

-1

300 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)

10

Error monitor for standard I/O (I/O1)

2

0 ~ 5

2

11

Error monitor for expansion I/O1 (I/O2)

1

0 ~ 5

1

12

Error monitor for standard I/O2 (I/O3)

0

0 ~ 5

0

13

Error monitor for expansion I/O3 (I/O4)

0

0 ~ 5

0

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor 24-V I/O power

supply errors)
(Main application version 0.55
or later)

3: Monitor (Monitor 24-V I/O power supply

errors only)

14

Number of ports used for remote input
via network I/F card

64

0 ~ 256

256

Multiple of 16

15

Number of ports used for remote output
via network I/F card

64

0 ~ 256

256

Multiple of 16

I/O1 through I/O4 indicate slot numbers.