IAI America E-Con User Manual

Page 85

Advertising
background image

77

6. SCON-C

Setting of Parameter No. 25

512-point mode

Solenoid mode 1

Solenoid mode 2

3 4 5

Category

Port

No.

Signal name

Symbol

Signal name

Symbol

Signal name

Symbol

0

PC1

Start position 0

ST0

Start position 0

STO

1

PC2

Start position 1

ST1

Start position 1

ST1

2

PC4

Start position 2

ST2

Start position 2

ST2

3 PC8

Start position 3

ST3 -

4 PC16

Start position 4

ST4 -

5 PC32

Start position 5

ST5 -

6 PC64

Start position 6

ST6 -

7 PC128

-

-

8

Command position

number

PC256

Not available.

-

Not available.

-

9

Forced brake

release

BKRL

Forced brake

release

BKRT

Forced brake

release

BKRL

10 Operation

mode

RMOD

Operation

mode RMOD

Operation

mode RMOD

11

Home return

HOME

Home return

HOME

-

12 Pause *STP Pause *STP

-

13

Positioning start

CSTR

Not available.

-

Not available.

-

14 Reset RES Reset RES Reset RES

Input

15

Servo ON command

SON

Servo ON command

SON

Servo ON command

SON

0

PM1

Position 0 complete

PE0

Rear end move

command 0

LS0

1

PM2

Position 1 complete

PE1

Rear end move

command 1

LS1

2

PM4

Position 2 complete

PE2

Rear end move

command 2

LS2

3

PM8

Position 3 complete

PE3

-

4

PM16

Position 4 complete

PE4

-

5

PM32

Position 5 complete

PE5

-

6

PM64

Position 6 complete

PE6

Not available.

-

7

PM128

Zone 1

ZONE1

Zone 1

ZONE1

8

Completed position

number

PM256

Position zone

PZONE

Position zone

PZONE

9

Operation mode

output

RMDS

Operation mode

output

RMDS

Operation mode

output

RMDS

10

Home return

complete

HEND

Home return

complete

HEND

Home return

complete

HEND

11

Position complete

signal

PEND

Position complete

signal

PEND

Not available.

-

12 Ready SV Ready SV Ready SV
13

Emergency stop

*EMGS

Emergency stop

*EMGS

Emergency stop

*EMGS

14 Alarm *ALM Alarm *ALM Alarm *ALM

Output

15

Battery alarm

*BALM

Battery alarm

*BALM

Battery alarm

*BALM

The signals indicated by * are ON in a normal state.
The signals denoted by “Not available” are not controlled (their ON/OFF status is indeterminable).
The battery alarm signal is always (mount to) ON if an incremental encoder is used.