IAI America SCON-C User Manual

Page 135

Advertising
background image




117

Position table (Field(s) within thick line must be entered.)

No.

Position

[mm]

Speed

[mm/s]

Acceleration

[G]

Deceleration

[G]

Push

[%]

Positioning

band [mm]

0

* * * * * *

1

150.00

200.00 0.30 0.10 0

0.10

:

























T1: 6 msec or more; time after selecting/entering a command position until the start input turns ON

(The scan time of the host controller must be considered.)

Caution: When the start signal turns ON, the position complete output will turn OFF and the moving

output will turn ON.
Always turn OFF the start signal after confirming that the start signal is currently ON and the
position complete output has turned OFF.
If the start input remains ON as shown below, the position complete output will not turn ON
even when the actuator movement is completed.












Speed

Position 1

Position 1

T

1

Command position

Start

Position complete


Completed position

Moving





Actuator movement

Deceleration 0.1 G

Positioning band

Acceleration 0.3 G

Start

Position complete

Moving

Actuator

Movement is complete.

Advertising