DeviceNet Gateway

[3] Mode setting switch

This switch is used to set the operation mode of the DeviceNet Gateway.
Operate the switch after turning off the DeviceNet Gateway power.
If any number between Nos. 1 and 5 is selected, the position table settings in the controller will
become invalid.








: ON X: OFF

SW1

I/O

bytes

No.

4 3 2 1

Description

Output Input

1 X X X X

Direct numerical specification mode,
maximum 4 axes

52 28

2 X

X X

Direct numerical specification mode,
maximum 6 axes

76 40

3

X X X

Direct numerical specification mode,
maximum 8 axes

100 52

4

X

Direct numerical specification mode,
maximum 10 axes

124 64

5

X X

Direct numerical specification mode,
maximum 16 axes

196 100

6 X X

X

Position-number specification mode

48

48

7 X X X

Command specification mode, Large

160

160

8 X

X

Command specification mode, Middle

128

128

9

X X

Command specification mode, Small

64

64


[4] External port switching input

The ON/OFF status of the teaching pendant/PC connector port can be switched using external
signals (no-voltage contact type).
The connector port is enabled when the port switch [10] on the DeviceNet Gateway is OFF. When the
input signal is ON, the port is also ON. (Refer to [10], “Port switch.”)


[5] Controller communication lines

This terminal is used to connect the communication lines to the SIO communication connector.


[6] DeviceNet communication connector

This connector is used to connect the DeviceNet communication lines.

SW1 turns ON when
tilted to the right.

Advertising