IAI America RCM-GW-DV User Manual
Page 82
76
DeviceNet Gateway
[3] “Position table data write (ROM)” command
Command name
CH+
PLC output (request)
PLC input (response)
+2 0DA0H
3 0
4 0
5 0
6
Axis number 0 to FH
7 (RSV)
Position table data
write (ROM) coil
write
8 (RSV)
Same as the requested
value, if the command was
successful.
+2 02E0H
3
0
Same as the requested
value, if the command was
successful.
4 0
5
0
00FFH = Data is being
written to ROM
0000H = Data has been
written to ROM
6
Axis number 0 to FH
7 (RSV)
Position table data
write (ROM)
completion coil
write
8 (RSV)
Same as the requested
value, if the command was
successful.
[4] “Present alarm code read” command
Command name
CH+
PLC output (request)
PLC input (response)
+2 0342H
3
0
Same as the requested
value, if the command was
successful.
4 0
Alarm
code
5 0
6
Axis number 0 to FH
7 (RSV)
Read a present
alarm code
8 (RSV)
Same as the requested
value, if the command was
successful.