76

DeviceNet Gateway

[3] “Position table data write (ROM)” command

Command name

CH+

PLC output (request)

PLC input (response)

+2 0DA0H

3 0
4 0
5 0
6

Axis number 0 to FH

7 (RSV)

Position table data
write (ROM) coil
write

8 (RSV)

Same as the requested
value, if the command was
successful.

+2 02E0H

3

0

Same as the requested
value, if the command was
successful.

4 0

5

0

00FFH = Data is being
written to ROM
0000H = Data has been
written to ROM

6

Axis number 0 to FH

7 (RSV)

Position table data
write (ROM)
completion coil
write

8 (RSV)

Same as the requested
value, if the command was
successful.



[4] “Present alarm code read” command

Command name

CH+

PLC output (request)

PLC input (response)

+2 0342H

3

0

Same as the requested
value, if the command was
successful.

4 0

Alarm

code

5 0
6

Axis number 0 to FH

7 (RSV)

Read a present
alarm code

8 (RSV)

Same as the requested
value, if the command was
successful.