IAI America RCM-GW-DV User Manual

Page 73

Advertising
background image

67

DeviceNet Gateway

PLC input = Status signal

1 word = 16 bits

(Sign)

(Sign)

Movement data position number

Control signal

Status signal

PLC output = Control signal

Position data specification (signed integer)

Position data specification (sign: 0 = Positive value, 1 = Negative value)

Current position data (signed integer)

Current position data (sign: 0 = Positive value, 1 = Negative value)

*1

*2

(2) Control/status signals of a simple direct operation axis

Each axis is assigned four words of PLC outputs (control signals) and three words of PLC inputs
(status signals), as shown below. The target position data and current position data are indicated by
signed 32-bit hexadecimal integers that are multiples of 0.01 mm.















































*1 m indicates the head address assigned to a simple direct operation axis. (m = 12 in the example

shown on the “Overall address configuration” page.)

*2 n indicates a sequential number, such as 0, 1, 2, …, assigned only to a simple direct operation

axis, counted from the first simple direct operation axis. (n = 0 to 4 in the example shown on the
“Overall address configuration” page.)