7. Connection With the Controller

7-1 Connection with the RC Data Input Pendant

(1) Connect the RC Data Input Pendant Cable to the “PORT IN” connector which is located on the front of

the controller. Always turn OFF the controller Port Switch first before connecting with regard to a

controller equipped with a PORT switch.

(2) After connecting, turn the controller PORT Switch ON with regard to a controller equipped with a PORT

switch.

7-2 How to Disengage the RC Data Input Pendant

Hold down the

key which is located in the upper of the key pad. Select “Complete” to

finish. Afterwards, turn the controller front SW side to OFF, and remove the Data Input Pendant

connector.

Afterwards, turn the controller front PORT switch to OFF, and remove the RC Data Input Pendant

connector with regard to a controller equipped with a PORT switch.

Operation:

1. Hold down the

key for more than 2.5 seconds.

2. Use the Arrow keys to select “Complete” Screen, and then press the Return key.

3. Turn the RC Controller PORT SW OFF with regard to a controller equipped with a PORT switch.

4. Remove the RC Data Input Pendant connector.

Caution: In the case of PCON, ACON, SCON, or ERC2, an instantaneous stop will be made when

the RC Data Input Pendant is disconnected. However, this is not an error.

Caution: In the case of the PCON, ACON, or ERC2 controller not having the AUTO/MANU switch,

set the TP Operation Mode to “Monitor 2” before disconnecting the RC Data Input Pendant

from the controller. (Refer to “8.10 TP Operation Mode.”)

In the case of ERC2 or when controller setting is made by connecting the RC Data Input

Pendant to the gateway unit or SIO converter:

• If the RC Data Input Pendant is disconnected while the setting of “Teach 1” or “Teach 2”

remains, I/O will become invalid and control from PLC will become impossible.

• If the RC Data Input Pendant is disconnected while the setting of “Monitor 1” remains, the

maximum speed will become the safety speed set for the parameter regardless of a

command from PLC.