8-1 Initial Screen During Power - UP

When power is connected to the controller and the controller PORT switch is ON, power is supplied

to the RC Data Input Pendant and operation starts.

Once the PORT switch on the controller equipped with the PORT switch is ON, power is supplied to

the RC Data Input Pendant and operation will begin.

Upon power-on, the LCD display screen (hereinafter called the “screen”) displays the RC Data Input

Pendant software version as follows:

Confirming Link
IAI RE DU V.

2.00

Once the RCP, RCS, E-Con, RCP2 and ERC controller connections are complete, the screen will

automatically move to the TP operation mode selection screen.

If a number of RCP, RCS, E-Con, RCP2, ERC controllers are connected, the screen will

automatically move to the controller select screen.

TP OpMode A.00
Slct(←,→) : Teach1

Fig. 8.2 TP operation mode selection screen

The TP operation mode is selected from the following four menus.

- Teach

1

PIO not allowed:

It is allowed to write position data and parameters, etc., in the controller

and command for actuator operation system.

With safety speed:

The maximum speed is the safety speed set for the parameter

regardless of the position data.

- Teach

2

PIO not allowed:

It is allowed to write position data and parameters, etc., in the controller

and command for actuator operation system.

Without safety speed: It is allowed to move at a speed registered on the position data.

- Monitor

1

PIO allowed:

Only monitoring is allowed. It is not allowed to write position data and

parameters, etc., in the controller.

With safety speed:

The maximum speed is the safety speed set for the parameter

regardless of the command from the PLC.

- Monitor

2

PIO allowed:

Only monitoring is allowed. It is not allowed to write position data and

parameters, etc., in the controller.

Without safety speed: It is allowed to move at a speed as commanded from the PLC.