11 end – IAI America RCM-P User Manual

Page 59

Advertising
background image

51

8-11 End

End is executed to save each setting or registration content of the RC Data Input Pendant.

Before removing the RC Data Input Pendant from the RC controller, be sure to execute End.

Operation:

Press the

key for more than 2.5 seconds.

In a case that data input ends, and the RC

Data Input Pendant needs to be removed

In a case that you reopen the connection from

the initial screen

Op. Start / End
* End DU = Efct

Op. Start / End
* Reconnection

Op. Start / End
* End DU = Non

Confirming Link
IAI RE DU V. 2.00

Turn the RC Controller PORT Switch to OFF.

Then, remove the connector.

Select Axis
* Axis No. 00

(in a case of multiple axes connection)

Or

OP Op Mode

A. 00

* Select (

Е, Ж): Teach 1

(in a case of single axis connection)

Caution: When multiple axes are connected with a controller link cable, after recycling power of a

controller that is not directly connected to the RC Data Input Pendant, please execute a

reconnect.

Caution: Disconnect the PCON, ACON, ERC2 controllers which are not equipped with the

AUTO/MANU switch after setting the TP operation mode to the “Monitor 2.” (Refer to 8.12 TP

Operation Mode.)

In the case of ERC2, and when the controller is set with the RC Data Input Pendant connected

with the gateway unit, SIO converter
I/O is disabled and control cannot be carried out from the PLC if they are disconnected

while the “Teach 1” and “Teach 2” are being set.

The maximum speed becomes a safe speed set on the parameter regardless of command

from the PLC if they are disconnected while the “Monitor 1” are being set.