Local programming, Setting output, Function – IDEC DS2_Series User Manual

Page 14: Instruction manual ds2 series, Run time, Start-up

Advertising
background image

Instruction manual

DS2 series

13

6.1. Local programming

The function programming and selection is made
using dip-switches located inside the receiver unit
lid.

The following table indicates the type of function and
relative position of the dip-switches.


Setting Output

Dip

N.

Function

Active Pos

Mode Analogue Switching

Serial

ON

Local

- -

-

1A

Programming

mode

Run

Time

OFF

Remote

See remote setting

ON

Complete -

-

Complete

Beam Status

Array

2A

Serial output

analysis mode

Start-up

OFF

Partial -

-

Partial

ASCII

ON

Reference = First

Beam

(closest to connector)

V=V

Res

*N

BEAM

[Top; ref]

Incr. Ramp(0-10V)

-

Partial

Top Beam

3A

Measurement

reference beam

Start-up

OFF

Reference = Last

Beam

V=10-V

Res

*N

BEAM

[Top; ref]

Decr. Ramp(10-0V)

Partial

Bottom Beam

ON

Top or Bottom

(Absolute Measure)

- -

-

4A

Measurement

analysis beam

Start-up

OFF

Total

(Relative Measure)

V=V

Res

*N

BEAM

[dark]

Partial

Total Beam

ON

Inactive Teach-in

(Normal mode)

- Presence

detection

-

1B

Teach-in

detection

analysis mode

Start-up

OFF

Active Teach-in

-

Conditional

presence detection

from Teach-in

-

ON

Absolute pos.

detection

-

Positional detection

of Teach-in ref.

object

-

2B

Teach-in

Mode

Start-up

OFF

Relative pos.

detection

-

Detection of Teach-

in reference object

-

ON

Normally

Open

-

Voltage on

switching device

during detection

-

3B

Switching

Output

Mode

Start-up

OFF

Normally

Closed

-

No voltage on

switching device

during detection

-

ON

No

Delay

- -

-

4B

Switching

Output

Delay

Start-up

OFF

100ms -

Restore from

detection

delay = 100ms

-

( - ) Shows that the state of considered dip-switch does not influence kind of output correlated; ouptut is old setting by state of

function of the others dip-switches.


The functions, with the exception of the programming mode, cannot be activated during device
functioning. The functions are activated at device powering.

1A 2A 3A 4A

ON

1B 2B 3B 4B

ON