Remote configuration from host user interface: synoptic table showing the output variation with
respect to the detection analysis mode configuration

Outputs

Function Mode

Analogue Switching Serial

ASCII

Complete

Beam

Status

Array

V=V

RES

*N

BEAM

[dark]

Binary

ASCII

Dark (default)

V=V

RES

*N

BEAM

[Top;

reference]

Top

Beam

Binary

ASCII

Top

Beam

Light

V=V

RES

*N

BEAM

[Top light;

reference]

Top Beam

(light)

Binary

ASCII

Dark (default)

V=V

RES

*N

BEAM

[Bottom;

reference]

Bottom

Beam

Binary

ASCII

Bottom

Beam

Light

V=V

RES

*N

BEAM

[Bottom

light; reference]

Bottom

Beam (light) Binary

ASCII

Dark (default)

V=V

RES

*N

BEAM

[0.5*(Top-

Bottom); reference]

Middle

Beam

Binary

ASCII

Middle

Beam

Light

V=V

RES

*N

BEAM

[0.5*(Top

light-Bottom light);

reference]

Middle

Beam (light) Binary

ASCII

Dark (default)

V=V

RES

*N

BEAM

[dark]

Total Beam

Binary

ASCII

Total

Beam

Light V=V

RES

*N

BEAM

[dark]

Total Beam

(light)

Binary

ASCII

Dark (default)

V=V

RES

*N

BEAM

[dark]

Total

Contiguous

Beam

Binary

ASCII

Total

Contiguous

Beam

Light V=V

RES

*N

BEAM

[dark]

Total

Contiguous

Beam (light) Binary

ASCII

Light Dark

(default)

V=V

RES

*N

BEAM

[dark]

N.

Transitions

Light Dark Binary

ASCII

Total

Beam

Dark Light V=V

RES

*N

BEAM

[dark]

N.

Transitions

Dark Light Binary


Some sections exclude each other (one or the other), i.e. if the Beam Status
Array
has been chosen as measurement 1, all the items of measurement 2
are deactivated. Another example: if Top Beam Dark has been chosen as
the first measurement, the operator can choose any other measurement
excluding the same type as the first and Beams Status Array. The items not
admitted become grey.
The settings will be memorised in the DS2 non-volatile memory pressing
the Update button.
The graphic will be restored with the last shape stored in the DS2 memory
by selecting the Download button.