IDEC DS2_Series User Manual

Page 23

Advertising
background image

DS2

series

Instruction

manual

22

Fig.19



After connection (see Fig. 19) and according to the local or remote programming, the graphic on the
left side of the user interface’s main window will visualise the following:

• the beams and object shape
• the Teach-in memorised in the receiver unit
• the indicators of the two measurements according to the programming mode selected
• local and remote configuration status


The bars that represent the light grid are automatically re-sized according the DS2 model
connected. The Configure button is activated and the Connect button becomes Disconnect.

Passing the cursor over the scanning area, the digital indicator below lights up showing the position
of the beam selected. The same happens in the Teach-in bar.
The current programming mode selected is visualised under the virtual panel. The programming
mode can be changed only using the dip-switch located on the DS2 light grid, also during device
powering. The dip-switch, corresponding to the programming mode, is the only one decoded in real
time. All the other switches require device turning off and re-powering. Misalignments can thus
occur between the real dip-switches and the virtual ones of the interface.