1.2. Selecting the device

The selection of the correct device version is linked to the detection area needed, which is considered
as the sensitive area height of the device as well as to the maximum operating distance, considered
as the distance between the emitter unit (TX) and receiver unit (RX) and optics interaxis.

Versions are available:

Operating distance

Detection field

interaxis

DS2-05-07-015-JV

5m

21 beams; h=150mm

6.75mm

DS2-05-07-030-JV

5m

42 beams; h=300mm

6.75mm

DS2-05-07-045-JV

5m

63 beams; h=450mm

6.75mm

DS2-05-07-060-JV

5m

84 beams; h=600mm

6.75mm

DS2-05-07-075-JV

5m

105 beams; h=750mm

6.75mm

DS2-05-07-090-JV

5m

126 beams; h=900mm

6.75mm

DS2-05-07-105-JV

5m

147 beams; h=1050mm

6.75mm

DS2-05-07-120-JV

5m

168 beams; h=1200mm

6.75mm

DS2-05-07-135-JV

5m

189 beams; h=1350mm

6.75mm

DS2-05-07-150-JV

5m

210 beams; h=1500mm

6.75mm

DS2-05-07-165-JV

5m

231 beams; h=1650mm

6.75mm

DS2-05-25-045-JV

10m 18

beams;

h=450mm 25mm

DS2-05-25-060-JV

10m

24 beams; h=600mm

25mm

DS2-05-25-075-JV

10m

30 beams; h=750mm

25mm

DS2-05-25-090-JV

10m

36 beams; h=900mm

25mm



The functions characterising the DS2 AREAscan

TM

light grids are available on all the versions that

consequently have the same operating modes.

The specific technical characteristics (e.g. resolution, sensitivity etc) remain the same for all the
versions, until differently indicated.

For food industry applications, please verify with DATASENSOR Technical Support the compatibility of
the materials of the light grid shell with the eventual chemical agents that are used in the production
process.