Inter-M HDCC-400 User Manual

Page 18

Advertising
background image

When the configuration is different from the auto-setting, you can change the value individually as below.
Set MUX A

This menu is for assignment the first level (A level) of MUX.

Cam : Dome camera ID

MUX : MUX ID

In

: Input of MUX

Out : Spot Output number of the MUX

(01: master keyboard, 02: slave keyboard 1, 03: slave keyboard 2, 04: slave keyboard 3)

1. Move the cursor (←) on the Cam column by the joystick.

2. Twist the joystick handle to change the value.

3. Move the cursor (←) on the MUX column by the joystick.

4. Twist the joystick handle to change the value.

5. Move the cursor (←) on the In column by the joystick.

6. Twist the joystick handle to change the value.

7. Press CTRL or

ESC

to exit.

8. To save data, move the joystick right on ‘Save and Exit’ row in MUX Config.

Press OFF to delete the camera number.

Set MUX B

This menu is for assignment the second level (B level) of MUX.

Cam : Dome camera ID

MUX : MUX ID

In

: Video Input number connected from the spot output of the first level’s MUX.

Out : Spot Output number of the MUX

(01: master keyboard, 02: slave keyboard 1, 03: slave keyboard 2, 04: slave keyboard 3)

For example: When the MUX channel is 64:

At the master keyboard, pressing 64 + CAM is operates as below.

MUX A: the multiplexer 04 outputs camera (ID=64) of the video input 16

to the spot output 1.

MUX B: the multiplexer 05 outputs the camera (ID=64) of the video input

13 to the spot output 1.

Cam<- MUX In Out

0001 001 01 01

Cam<- MUX In Out

0001 005 01 01

Cam<- MUX In Out

0064 005 13 01

Cam<- MUX In Out

0064 004 16 01

Advertising