RS232 TO RS485
CONVERTER

RS232 TO RS485
CONVERTER

When you control PTZ cameras on many DVRs, you need RS232 to RS485 converter.

PTZ cameras are connected to RS232 to RS485 converter by the RS232 port of the DVR and the keyboard is

connected through the RS485 port of the DVR.

Follow as below.

1. Connect RS485 cable between RS485 Port of DVR and the DOME1 port of the keyboard.
2. Connect RS232 cable between RS-232 Port of DVR and the RS232 Port of the RS232 to RS485 converter.
3. Connect PTZ cameras to the RS485 Port of the RS232 to RS485 converter.
4. Repeat the step 1-3 each DVR.
5. Set the system ID number of each DVR from 1 to the last DVR increasing 1.
6. Set the network menu of the keyboard as below.

Note: The baud rate of DOME1 should be the same as one of the RS485 of the DVR.

7. How to setup DVR:

A. Switch the DVR on.

B. Enter the Menu according to the DVR’s instruction manual.

C. Change the Port to “RS485” of the remote control in the devices menu.

D. Confirm matching the setup of RS485 with the keyboard.

Ex: Baud Rate:9600,Data Bit:8,Stop Bit:1, Parity:None)

E. Change the Remote Control to “Remote Control2” in the devices menu.

F. Change the Port to “RS232” in the PTZ menu of the camera of the devices menu.

G. Confirm matching the setup of RS232 of the PTZ menu with PTZ cameras.

H. Set the PTZ menu according to PTZ cameras.(PRODUCT and ID)

Note: The baud rate of all PTZ cameras should be used one speed type(ex. All 9600 or all 2400)

Set Baud Rate

DOME1

:

9600

DOME2 :

9600

RS232

:

9600

Com Ports

DOME1

: DVR5

DOME2 : NONE
RS232

: NONE

Installation of DVR5 protocol when many DVR use.