8

Installation

A1

A2

+

VD

C

INP

UT

-VD

C

INP

UT

R502

C506

SO501

C504

C505

L501

D501

Q503

Q501

Q504

R

50

1

IL501

Q502

TB501

C501

C502

C507

R

503

JP501

3

2

1

POWER

S3

S2

S1

MIN SPD

IR COMP

CUR LIMIT

ACCEL

MAX SPD

Figure 4. Jumper 501 (JP501)

Jumper 501

Jumper 501 (JP501)

LEESON 17529X.00 series drives are shipped with JP501 open

(no jumper applied). This allows you to use 24 VDC motors with

the 175290.00 and 175291.00, or 48 VDC motors with the

175292.00. To use lower voltage DC motors (12 VDC or 36 VDC,

respectively) jumper pins 2 and 3 with the jumper provided. See

Figure 4 for the location of JP501.

175290.00 = 16 Amp 12/24 VDC
175291.00 = 60 Amp 12/24 VDC
175292.00 = 60 Amp 36/48 VDC