Acceleration (accel) – LEESON Chassis Mount PWM Control: 175292.00 User Manual

Page 29

Advertising
background image

23

ACCELERATION (ACCEL)

The ACCEL setting determines the time the motor takes to

accelerate to a higher speed. See

Specifications on page 1 for

approximate acceleration times. The ACCEL setting is factory set

to its minimum value (full CCW).

To calibrate ACCEL:

1. Set the ACCEL trimpot full CCW.

2. Apply power to the drive and turn the main speed adjust

potentiometer full CW. If an input voltage signal is used instead

of a speed adjust pot, set the input signal to maximum. Note

the time that the drive takes to accelerate to the desired speed.

3. Adjust the ACCEL trimpot until the desired acceleration time is

reached. Turn the ACCEL trimpot CW to increase the

acceleration time, and CCW to decrease the acceleration time.

Calibration