Installation

Connect a DC motor to PCB terminals A1 and A2 as shown in

Figure 7, page 13. Ensure that the motor voltage rating is

consistent with the drive’s output voltage.

Power input

Warning

This drive is not diode-protected from reverse battery voltage.
You must assure that POS (+) is wired to +VDC IN and NEG
(–) is wired to –VDC IN.

ƽ

Connect the DC power leads to terminals + VDC IN and - VDC IN,

or to a single-throw, single-pole master power switch as shown in

Figure 7, page 13 (recommended).

Fuse

Wire a power input fuse between the stop switch (if installed) and

the + VDC IN terminal on the circuit board. The fuse should be

rated at 150% of input voltage and 150 - 200% of maximum motor

nameplate current.