C.Setting Examples

Here is some VoIP call out routing table setting examples below:

a.

Define wait time and digits for destination phone number

MaxDigits:

10

FirstDigitTime(Sec):

30

OtherDigitTime(Sec):

5


In this case, when user picks up the phone, the VoIP Gateway will generate 30
seconds (defined on FirstDigitTime) dial tone for user press DTMF for
destination phone number, After user press first digit DTMF from phone set (for
example, 0, the VoIP Gateway will wait 5 seconds (defined on OtherDigitTime)
to press the rest phone number digits, if user did not press any key within first
30 seconds, the VoIP Gateway will generate the busy tone to terminate the call.
After user press first digit and did not key any key within 5 seconds, for example,
like 601 it will call out 601 after 5 seconds, but if user press 601#, it will direct
call out 601 immediately without waiting rest key.

In this case, the Max Digits is setting to 10, so if user dial 0212345678, 10 digits
phone number, it will call out immediately without wait 5 seconds or # key, that
mean it will not accept phone number more than 10 digits like 02123456781, if
user press that phone number, it still call out the number to 0212345678
because maximum digits for phone number is 10.


b.

VoIP call out by IP:

Index

Remark

Area Code Min Digits

Max Digits

IP Address

Strip Prefix

Profile

Delete

1 NY_office 6

172.16.7.1

33

Delete

In this case, we assume that we have another VoIP Gateway locate at New York
office and the IP is 172.16.7.1 , when we press any phone number prefix is 6 will
call to that VoIP Gateway, for example, if we dial 601, the VoIP will Call out 601
to another VoIP Gateway locate at IP 172.16.7.1, you can check the real call out
IP and phone number at the VoIP Setup/ Port Status: