11

TEST THE SYSTEM

Turn on power. Test all controls and safety devices to
make sure they are working properly. It will be
necessary to refer back to page 6 for fine adjustment
of the limit switches.

IMPORTANT NOTES:

Do not leave operator power on unless all safety
and entrapment protection devices have been
tested and are working properly.

Be sure you have read and understand all Safety
Instructions included in this manual.

Be sure the owner or person(s) responsible for
operation of the door have read and understand
the Safety Instructions, know how to electrically
operate the door in a safe manner, and know how
to use the manual disconnect operation of the
door operating system.

WARNING

CAUTION

WARNING

WARNING

DO NOT PLACE HANDS OR TOOLS IN OR NEAR
THE OPERATOR WHEN THE POWER IS ON OR
WHEN TESTING CONTROL OR SAFETY
DEVICES. ALWAYS DISCONNECT POWER
BEFORE SERVICING OR ADJUSTING THE
OPERATOR.

The operator has been pre-wired to accept
connection of a reversing edge device. Connect the
normally open contacts to terminals T4 and T8 on the
low voltage terminal block. A cut-off switch will de-
activate the safety device during the last few inches of
the door's downward travel.

IF CONTROL STATION CANNOT BE INSTALLED WHERE
DOOR IS VISIBLE, OR IF ANY DEVICE OTHER THAN
THE CONTROL STATION IS USED TO ACTIVATE THE
DOOR,

A REVERSING EDGE MUST BE INSTALLED ON

THE BOTTOM OF THE DOOR. FAILURE TO INSTALL A
REVERSING EDGE UNDER THESE CIRCUMSTANCES
MAY RESULT IN SERIOUS PERSONAL INJURY OR
DEATH TO PERSONS TRAPPED BENEATH THE DOOR.

CONNECT REVERSING EDGE DEVICE (OPTIONAL)

NOTICE:
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference, in which case the
user will be required to correct the interference at his own expense.

WARNING

CAUTION

WARNING

WARNING

HOW TO ORDER REPAIR PARTS

OUR LARGE SERVICE ORGANIZATION

SPANS AMERICA

INSTALLATION AND SERVICE INFORMATION

ARE AVAILABLE 6 DAYS A WEEK

CALL OUR TOLL FREE NUMBER - 1-800-528-2806

HOURS 7:00 TO 3:30 p.m. (Mountain Std. Time)

MONDAY Through SATURDAY

WHEN ORDERING REPAIR PARTS

PLEASE SUPPLY THE FOLLOWING INFORMATION:

PART NUMBER DESCRIPTION MODEL NUMBER

ADDRESS ORDER TO:

THE CHAMBERLAIN GROUP, INC.

Electronic Parts & Service Dept.

6020 S. Country Club Road

Tucson, AZ 85706

MAINTENANCE SCHEDULE

Use SAE 30 Oil (Never use grease or silicone spray).

U

Repeat ALL procedures.

Motor grease fitting to be greased every 12,000 Hrs. of Motor operation. Recommended grease for

standard service conditions is Polyrex EM (Exxon Mobile).

Inspect and service whenever a malfunction is observed or suspected.

CAUTION: BEFORE SERVICING, ALWAYS DISCONNECT OPERATOR FROM POWER SUPPLY.

Check at the intervals listed in the following chart.

EVERY

EVERY

EVERY

ITEM

PROCEDURE

3 MONTHS

6 MONTHS

12 MONTHS

Drive Chain

Check for excessive slack.
Check & adjust as required.
Lubricate.*

z

U

Sprockets

Check set screw tightness

z

U

Fasteners

Check & tighten as required

z

U

Manual Disconnect

Check & Operate

z

U

Bearings & Shafts

Check for wear & lubricate

z

U

Advertising