Three phase field wiring, Warning caution warning warning, Control wiring three phase field wiring – LiftMaster GH5HP 5 HP Heavy Industrial-Duty Gear-Reduced Hoist Operator User Manual

Page 13: Mount warning notice, Special control wiring

Advertising
background image

8

13

CONTROL WIRING

THREE PHASE FIELD WIRING

Standard C2 or B2 Wiring
Standard operators are shipped from the factory with
jumper set for C2 wiring, which requires constant
pressure on button to close the door. If momentary
contact on close direction is desired (B2 wiring) you
must include an entrapment protection device. See
close control jumper setting below.

Constant pressure on close (C2 wiring)
Red jumper wire was placed on terminal #2 in
electrical enclosure. The operator will require
constant pressure on close control in order to keep
door moving in the close direction.

Momentary contact on close (B2 wiring)
Move red jumper wire from terminal #2 to terminal
#3. The operator will require only momentary
contact to close the door.

LOCATING THE CONTROL STATION
All operators are supplied with some type of control station. Gener ally a three button station
(OPEN/CLOSE/STOP) is provided. A two-position key switch or control station (OPEN/CLOSE) may be added or
substituted when requested at the time of order. Mount the control station near the door.

WARNING

CAUTION

WARNING

WARNING

INSTALL THE CONTROL STATION WHERE THE
DOOR IS VISIBLE, BUT AWAY FROM THE DOOR AND
ITS HARDWARE. IF CONTROL STATION CANNOT BE
INSTALLED WHERE DOOR IS VISIBLE, OR IF ANY
DEVICE OTHER THAN THE CONTROL STATION IS
USED TO ACTIVATE THE DOOR,

A REVERSING EDGE

MUST BE INSTALLED ON THE BOTTOM OF THE
DOOR. FAILURE TO INSTALL A REVERSING EDGE
UNDER THESE CIRCUMSTANCES MAY RESULT IN
SERIOUS INJURY OR DEATH TO PERSONS
TRAPPED BENEATH THE DOOR.

W A R N I N G

TO PREVENT ENTRAPMENT

DO NOT START DOOR DOWNWARD

UNLESS DOORWAY IS CLEAR

OPEN

CLOSE

CLOSE

STOP

Control Station

WARNING Notice

Push

Buttons

IMPORTANT: Mount WARNING NOTICE beside or
below the push button station.

MOUNT WARNING NOTICE

DETERMINE WIRING TYPE
Refer to the wiring diagram located on the inside cover the electrical box to determine the type of control wiring.

SPECIAL CONTROL WIRING

If your operator was shipped from the factory with
non-standard control wir ing or with optional
accessories that require addition instructions, refer to
the wiring diagram(s) indicated in the special control
wiring data box. When a replacement wiring diagram
is present, wiring diagrams in this manual will not
apply. Refer only to the replacement wiring diagram
for all connections.

IMPORTANT NOTE: If your wiring diagram is
missing, or you are unsure of the wiring type for
your operator, contact the customer service
department @ 1-800-528-2806.