Operator notes, Specifications, Safety – LiftMaster GH5HP 5 HP Heavy Industrial-Duty Gear-Reduced Hoist Operator User Manual

Page 19: Motor, Drive system, Electrical, Weights and dimensions

Advertising
background image

2

SPECIFICATIONS

19

SAFETY

REVERSING EDGE:.......(Optional) Electric or pneumatic

sensing device attached to the bottom edge of door.

A REVERSING EDGE IS STRONGLY RECOMMENDED
FOR

ALL COMMERCIAL OPERATOR INSTALLATIONS.

REQUIRED WHEN THE 3 BUTTON CONTROL STATION
IS OUT OF SIGHT OF DOOR OR ANY OTHER
CONTROL (AUTOMATIC OR MANUAL) IS USED.

MOTOR

TYPE: ....................................AC Synchronous

continuous duty
brake motor

ENCLOSURE:.......................ODP NEMA 184TC face

mount.

HORSEPOWER: ...................5 HP

Three phase

SPEED: .................................1725 RPM

VOLTAGE: .............................208/230 & 460 Three phase

OR 575V Three Phase

BRAKE HOLDING
FORCE:
.................................15 Ft-Lbs

DRIVE SYSTEM

CONTINUOUS
POWER RATING:
.................1000 Ft-Lbs/Sec

GEAR BOX: ..........................Worm gear

LUBRICATION: .....................Oil Bath

RATIO: ..................................45:1

OUTPUT SPEED: .................38 rpm

DOOR SPEED: .....................5” per sec.

depending on door

OUTPUT SHAFT:..................1.5” Dia. with 3/8” keyway

OVERHUNG LOAD:..............1752 Lbs.

(1.5” from output bearing face)

HOIST WHEEL: ....................Standard mounting on
left or right side.

DISCONNECT:......................Floor level chain hoist with

electrical interlock for
emergency manual door
operation.

ELECTRICAL

TRANSFORMER: ...............3PH: 208/230/480 VAC 24VAC

OR 3PH: 575VAC-24VAC

CONTROL STATION: ........NEMA 1 three button station.

OPEN/CLOSE/STOP

WIRING TYPE: ...................Standard C2 Wiring- Standard

operators are shipped from the factory set for C2 wiring,
which requires momentary contact to open, constant
pressure to close, stop on release.

Optional B2 Wiring- Which requires momentary contact to
open, close and stop. See schematic diagram on page 12
for instructions on how to configure the operator for B2
wiring

Wiring for sensing device to reverse and auxiliary devices to
open and close with open override.

LIMIT ADJUST: ..................Rotary driven, fully

adjustable screw type cams. Adjustable to 50 feet.
(Provides 2 minutes of operator running time).

DUTY CYCLE: ....................25 Reversing cycles per hour

DELAY ON REVERSE:.......Standard

OPERATOR NOTES

18.00”

See

Note #1

7.87”

11.61”

8.50”

40.25”

26.38”

WEIGHTS AND DIMENSIONS

HANGING WEIGHT: .......300 LBS.

SHOULD THE CHAIN OR OPERATOR FAIL AS AN
ADDED SAFETY FEATURE, IT IS RECOMMENDED TO
USE STOP LOCK BEARINGS ON THE DOOR SHAFT
TO PREVENT THE DOOR FROM CRASHING DOWN.

NOTES:
1) Output Shaft 1.5” Dia. with 3/8” Keyway.

Hand Chain Wheel

2.38”

Advertising