14

7

Remove the cover from the electrical enclosure. Inside this enclosure you will find the wiring diagram(s)
for your unit. Refer to the diagram (glued on the inside of the cover) for all connections described below.
If this diagram is missing, call the number on the back of this manual. DO NOT INSTALL ANY WIRING OR
ATTEMPT TO RUN THIS OPERATOR WITHOUT CONSULTING THE WIRING DIAGRAM.

POWER WIRING CONNECTIONS

WARNING

CAUTION

WARNING

WARNING

DISCONNECT POWER AT THE FUSE BOX BEFORE
PROCEEDING.
OPERATOR MUST BE PROPERLY GROUNDED AND
PERMANENTLY WIRED IN ACCORDANCE WITH
LOCAL ELECTRICAL CODES. NOTE: THE
OPERATOR SHOULD BE ON A SEPARATE FUSED
LINE OF ADEQUATE CAPACITY.
ALL ELECTRICAL CONNECTIONS MUST BE MADE
BY A QUALIFIED INDIVIDUAL.

WARNING

CAUTION

WARNING

WARNING

TO AVOID DAMAGE TO DOOR AND OPERATOR,
MAKE ALL DOOR LOCKS INOPERATIVE. SECURE
LOCK(S) IN "OPEN" POSITION.
IF THE DOOR LOCK NEEDS TO REMAIN
FUNCTIONAL, INSTALL AN INTERLOCK SWITCH.

1.

Be sure that the power supply is of the correct

voltage, phase, frequency, and amperage to supply
the operator. Refer to the operator nameplate on the
cover, and motor nameplate.

2.

Recommended conduit entrance to be 7/8”

Dia. to be drilled by installer. Take care not to
damage the internal components, see below. Bring
supply lines to the operator and connect wires to the
terminals indicated on the WIRING CONNECTIONS
DIAGRAM.

DO NOT TURN POWER ON UNTIL YOU HAVE
FINISHED MAKING ALL POWER AND CONTROL
WIRING CONNECTIONS AND HAVE COMPLETED
THE LIMIT SWITCH ADJUSTMENT PROCEDURE.

IMPORTANT: THIS UNIT MUST BE PROPERLY
GROUNDED. A GROUND SCREW IS SUPPLIED IN
THE ELECTRICAL BOX FOR CONNECTION OF
THE POWER SUPPLY GROUND WIRE. FAILURE
TO PROPERLY GROUND THIS UNIT COULD
RESULT IN ELECTRIC SHOCK AND SERIOUS
INJURY.

POWER WIRING

WARNING

Do Not Run Power &

Control Wiring in the

Same Conduit

Recommended location for
7/8” Dia Holes for
power wiring conduit access

REPAIR PARTS KITS – ELECTRICAL BOX

K74-18346 LIMIT SHAFT ASSEMBLY KIT

Item

L1
L2
L3
L4
L5
L6
L7
L8
L9

L10
L11

Description
Limit Shaft
Flange Bearing
Bearing Seal, 3/8” I.D.
Limit Nut
Neoprene Gasket
Sprocket 48B18 x 3/8” Bore
Washer, Shim
Screw, #8-32
Nut , #8-32 Serrated Flange
Roll Pin, 1/8 DIA. x 1” Long
E Ring, 3/8”

Qty

1
2
2
2
2
1

32

4
4
1
2

P/N

11-10480
12-10481
12-10483
13-10024
13-10516
15-48B18AXX
80-10026
82-PX08-10T
84-FN-08
86-RP04-100
87-E-038

COMPLETE ELECTRICAL BOX KITS

Item

1
2
3
4
5
6
7
8
9

10
11
12
13
14
15
16
17
18

Description
Contactor
Din Rail
Electrical Panel (Reworked)
Transformer 230/460V 3 HP
24VAC DPDT Relay
24VDC DPDT Relay
(See Overloads)
Contact Block
Fuse 4 Amp 125V
Terminal Block, 14 Position
Enclosure 12 x 10 x 6
Washer, #8 Terminal
Screw, #10-32 x 3/8” Long
Screw, #8-32 x 1/4” Long
Screw, #8-32 x 11/16” Long
Screw, #8-32 x 3/8” Long
Flatwasher, #10
Lockwasher, #10

Qty

1
1
1
1
1
1
1
2
1
1
1
1
4
8
6
2
4
4

P/N

03-8224-D
03-ABDIN-4
10-10477-1
21-xxxx
24-24-1
24-264-4
25-xxxx
27-8002-D
35-204
42-114
44-18194
80-10054
82-HS10-06
82-PX08-04T
82-PX08-10T
82-WS08-06G
85-FW-10
85-LS-10

Below are replacement kits available for your operator. For replacement of electrical box, motor or brake components be sure
to match model number of your unit to kit number below to ensure proper voltage requirements. Optional modifications and/or
accessories included with your operator may add or remove certain components from these lists. Please consult a parts and
service representative regarding availability of individual components of kits specified below. Refer to page 11 for all repair
part ordering information.

Overloads

25-4018-D Overload Model GH5HP23M
25-4010-D Overload Model GH5HP43M
25-4008-D Overload Model GH5HP53M

Transformers

21-3460-1

Model GH5HP23M &
Model GH5HP43M

21-3575-1

Model GH5HP53M

Item

S1
S2
S3
S4
S5
S6
S7
S8
S9

S10
S12

P/N

10-10476
10-10478
10-12553
18-10036
23-10041
31-12378
82-PX04-12
82-PX04-20
82-PX06-16
82-PX08-04T
84-LH-06

Description
Depress Plate
Aux. L/S Mtg. Bracket
Nut Plate, Switch
Spring, Depress Plate
Limit Switch
Standoff, Limit Switch
Screw, #4-40 x 3/4” Long
Screw, #4-40 x 1-1/2” Long
Screw, #6-32 x 1” Pan Hd Phillips
Screw, #8-32 x 1/4” Long
Locknut, #6-32 Nylon Hex

K72-18345 LIMIT SWITCH ASSEMBLY KIT

Qty

1
1
4
2
4
4
4
4
2
2
2

Electrical Box Kits

74-17965

Model GH5HP23M

74-17966

Model GH5HP43M

74-18081

Model GH5HP53M

Advertising