Programming, Keypad – LiftMaster TAC2D TAC Retrofit System for *1812 User Manual

Page 2

Advertising
background image

2

PROGRAMMING

» KEYPAD

NOTE: Use the STAR Key “*” to cancel any input.

PROGRAMMING INSTRUCTION

SYNTAX

KEYSTROKES

General Programming

Master Code + Command

1234 + 1 (12,123)

Code Programming

Master Code + Command + Code

1234 + 1 (12) + 1234

Relay Programming

Master Code + Command + Setting

1234 + 123 + 1234

Level Adjustment

Master Code + Command + Setting

1234 + 12 + 1-3

NOTE: Keypad commands are to be entered in a single string to result in success (indicated by double high success tone). Stop and go
keystrokes will result in negative tones (low single and triple fail tones).

CHANGE THE MASTER CODE

1. Enter the Master Code:

?

?

?

?

2. Enter the Program Code:

0

9

The unit will beep.

3. Enter:

#

#

#

4. Enter the new Master Code:

?

?

?

?

The unit will beep.

Write down the Master Code and store in a secure location.

MICROPHONE SENSITIVITY

Allows the resident to hear the visitor at the unit,
1 = Low, 2 = Medium and 3 = High. Default level is 2.

1. Enter the Master Code:

?

?

?

?

2. Enter the Program Code:

0

7

3. Enter the Volume Level:

1

or

2

or

3

SPEAKER VOLUME

Allows the visitor to hear the resident at the unit,
1 = Low, 2 = Medium and 3 = High. Default level is 2.

1. Enter the Master Code:

?

?

?

?

2. Enter the Program Code:

0

6

3. Enter the Volume Level:

1

or

2

or

3

ADJUST RELAY OUTPUT TIME (RELAY 1)

The amount of time (in seconds) the relay remains active.
Default level is 0.5 seconds.

1. Enter the Master Code:

?

?

?

?

2. Enter the Program Code:

0

2

4

3. Enter the Output Time (in seconds):

?

?

?

?

Example:

0000 = 0.5 Seconds (Minimum)
0010 = 10 Seconds
8000 = 8000 Seconds (Maximum)

ADJUST RELAY OUTPUT TIME (RELAY 2)

The amount of time (in seconds) the relay remains active.
Default level is 0.5 seconds.

1. Enter the Master Code:

?

?

?

?

2. Enter the Program Code:

0

2

5

3. Enter the Output Time (in seconds):

?

?

?

?

Example:

0000 = 0.5 Seconds (Minimum)
0010 = 10 Seconds
8000 = 8000 Seconds (Maximum)

ENABLE TELCO MODE

Telco Mode is using the main telephone line for the unit’s
communications to the house or complex.

1. Enter the Master Code:

?

?

?

?

2. Enter the Program Code:

0

4

ENABLE INTERCOM (NO TELCO) MODE

1. Enter the Master Code:

?

?

?

?

2. Enter the Program Code:

0

3

ENABLE INDEPENDENT RELAY OUTPUT CONTROL

1. Enter the Master Code:

?

?

?

?

2. Enter the Program Code:

0

2

3

ENABLE PARALLEL RELAY OUTPUT (DEFAULT)

1. Enter the Master Code:

?

?

?

?

2. Enter the Program Code:

0

2

1