AUDIO FEEDBACK FROM THE UNIT:

1 Low Tone Beep = Failure

2 Two High Tone Beeps = Valid sequence

3 Low Tone Beep = Error or invalid sequence

NOTE: Use the STAR Key “*” to cancel any input.

NOTE: Keypad commands are to be entered in a single string to result in success (indicated by double high tone).
Stop and go keystrokes will result in negative tones (low single and triple fail tones).

PROGRAMMING

» QUICK REFERENCE

KEYPAD PROGRAMMING

PROGRAMMING NUMBER

DESCRIPTION OF TASK

FACTORY SETTING

PROGRAMMING PROCEDURE

1

Trigger Relay One

Master Code (4 digits) + 1

2

Trigger Relay Two

Master Code (4 digits) + 2

7

Delete User Code

Master Code (4 digits) + 7 + User Code that is to be deleted
(4 digits)

9

Enter User Code

Master Code (4 digits) + 9 + New User Code
(4 digits) + Relay Associated with the User Code (1 or 2)

03

Enable Intercom (No-Telco) Mode

Master Code (4 digits) + 03

04

Enable Telco Mode

Enabled

Master Code (4 digits) + 04

06

Speaker Volume

Level 2

Master Code (4 digits) + 06 + Volume Level
(1 = Low, 2 = Medium or 3 = High)

07

Microphone Sensitivity

Level 2

Master Code (4 digits) + 07 + Volume Level
(1 = Low, 2 = Medium or 3 = High)

09

Change the Master Code

Master Code (4 digits) + 09 + ### + New Master Code
(4 digits)

51

Create Temporary (1 Shot) Code

Master Code (4 digits) + 51 + New Temporary (1 Shot) Code
(4 digits) + Relay Associated with the User Code (1 or 2)
(Expires after 24 hours)

52

Enable Vacation (Lock Down)
Mode

Disabled

Master Code (4 digits) + 52

53

Disable Vacation (Lock Down)
Mode

Master Code (4 digits) + 53

54

Engage Party Mode (Relay 1)

Disabled

Master Code (4 digits) + 54

56

Engage Party Mode (Relay 2)

Disabled

Master Code (4 digits) + 56

021

Enable Parallel Relay Output

Enabled

Master Code (4 digits) + 021

023

Enable Independent Relay Output
Control

Disabled

Master Code (4 digits) + 023

024

Adjust Relay Output Time (Relay 1)

.5 Seconds

Master Code (4 digits) + 024 + Relay Output Time (0000-8000
Seconds) NOTE: Relay output time is ALWAYS 4 digits.

025

Adjust Relay Output Time (Relay 2)

.5 Seconds

Master Code (4 digits) + 025 + Relay Output Time (0000-8000
Seconds) NOTE: Relay output time is ALWAYS 4 digits.

DIRECT COMMANDS FROM THE UNIT KEYPAD

KEYSTROKES

ACTION

User Code + 1

Triggers Relay 1

User Code + 2

Triggers Relay 2