Wiring, Wire the kpr2000, Wiring examples – LiftMaster KPR2000 Single Entry Access Control Keypad and Proximity Reader User Manual

Page 4

Advertising
background image

4

WIRING

Red

Black

Normally Open

Blue

Purple

Gray

Pink

Install a 1N4007 or
equivalent diode.

Common

(1 Amp Maximum)

Wire Insulation Color

Wiring Function

Notes

Basic Stand Alone Wiring

Red

Power +

12~24 Volts DC Regulated Power Input

Black

Power -

12~24 Volts DC Regulated Power Input

Pink

Power -

Ground Conductor

Blue

Relay NO

Normally Open Relay Output (Install diode provided)

Purple

Relay Common

Common Connection for Relay Output

Orange

Relay NC

Normally Closed Relay Output (Install diode provided)

Pass-Through Wiring (Wiegand Master and Remote)

Green

Data 0

Wiegand Output (Pass-through)/Input (Stand Alone) Data 0

White

Data 1

Wiegand Output (Pass-through)/Input (Stand Alone) Data 1

Pink

Ground

Advanced Input and Output Features

Yellow

REX

Request To Exit (REX) Input

Gray

Alarm Output

Negative contact for Alarm

Brown

Contact Input

Door/Gate Contact Input (Normally Closed)

Gate/Door Operator or Fail-Secure Strike

Red

Black

Pink

Orange

Purple

Normally Closed

Install a 1N4007 or
equivalent diode.

Common

Gray

(1 Amp Maximum)

Magnetic Lock or Fail-Safe Strike

KPR2000

External Alarm

External Alarm

External Alarm

KPR2000

Green (Data 0)

White (Data 1)

Pink (must connect for ground reference)

Maximum of 500 feet (152.4 m)

Red

Black

Normally Open

Blue

Purple

Gray

Pink

Install a 1N4007 or
equivalent diode.

Common

(1 Amp Maximum)

Black

Pink

Red

Networking Two KPR2000 Units or Connecting to an Access Control System

3

Wire the KPR2000.

WIRING EXAMPLES:

KPR2000 Stand-Alone

(Master Unit)

KPR2000 Stand-Alone

(Remote Unit)

Advertising