7

ACCESS CONFIGURATION: CARD + PIN

PROGRAMMING

ACCESS CONFIGURATION: CARD ONLY

USING MANAGER CARDS

KPR2000 managers can use manager cards to program user cards into
and out of the system. There are two pre-programmed manager cards
(an Add Card, and a Delete Card) to allow rapid card enrollment. This is a
form of Auto User ID enrollment and is only available in “Card Only”
configuration.

Programming Step Keystroke Combination

Add a User Card

1. (Read Manager Add Card)

2. (Read User Card)

Repeat Step 2 for additional user cards

3. (Read Manager Add Card)

Delete a User Card

1. (Read Manager Delete Card)

2. (Read User Card)

Repeat Step 2 for additional user cards

3. (Read Manager Delete Card)

ADD A CARD + PIN USER

Programming Step

Keystroke Combination

1. Enter Program Mode

(Master Code) #

2. Add a User Card

Assigns card number
to User ID

1 (Read Card) #

OR

1 (User ID) # (Read Card) #

3. Exit Program Mode

4. Add PIN

(Read Card) (1234#) (New PIN #) (New
PIN #)
This operation is executed from outside of
Program Mode

CHANGE PIN

Allows card user to update the PIN for their card + PIN User ID. This
operation is executed from outside of Program Mode.

Programming Step

Keystroke Combination

1. Change PIN using a

Card

OR

1. Change PIN using PIN

(Read Card) (Old PIN #) (New PIN #)
(New PIN #)

(User ID) (Old PIN #) (New PIN #) (New
PIN #)

DELETE CARD BY USER ID

Deleting by ID number will clear cards and PINs.

Programming Step

Keystroke Combination

1. Enter Program Mode

(Master Code) #

2. Delete User Card by

User ID

2 (User ID) #

3. Exit Program Mode

ADVANCED PROGRAMMING

Panic Codes

There is a section of the KPR2000 memory set aside specifically for cards and PINs to be used in the instance of an emergency. There are several
rules that guide the use of these cards/PINs:

Panic Codes activate the relay and the alarm/alarm output.

Panic Codes use a User ID of 2001~2010 ONLY.

Panic Codes must be unique. Duplicated Codes act as a normal User Code.

Programming Step

Keystroke Combination

1. Enter Program Mode

(Master Code) #

2. Add a User Card

OR

2. Delete a User Card

8 (User ID Number) # (Card) #

2 (User ID Number) #

3. Exit Program Mode

ADD OR DELETE A PANIC PIN

ADD OR DELETE A PANIC CARD

Programming Step

Keystroke Combination

Panic PIN Codes: Add or Delete a PIN

1. Enter Program Mode

(Master Code) #

2. Add a PIN

OR

2. Delete a PIN

8 (User ID Number) # (PIN) #