background image

Alarm

Reset the KPR2000

This will reset the KPR2000 to the factory default but all card/PIN
information will still be retained. This will also require reprogramming of
the Master Add and Delete Cards. NOTE: This is useful if the original
Master Add and Delete Cards have been lost.

1. Power the KPR2000 down.

2. Press and hold the ✱ button while power is restored to the KPR2000.

3. Release the button and wait until the amber LED shines.

4. Present any 26 bit proximity card or the Manager Add Card (provided)

to the KPR2000. This card is now the Manager Add Card.

5. Present any 26 bit proximity card or the Manager Delete Card

(provided) to the KPR2000. This card is now the Manager Delete
Card.

When the red LED begins to blink, the KPR2000 has been successfully
reset.

Operation Status

Red LED

Green LED

Amber LED

Sounds

Power On

Flashing

Short Single Beep

Standby

Flashing

Press Keypad

Flashing

Short Single Beep

5 Second Time-out

Flashing

3 Short Beeps

Enter Master Code Entry Mode

ON

Short Single Beep

In Program Mode

ON

Single Flash

Short Single Beep

Entered Single Program Step Successfully

ON

Single Flash

Short Single Beep

Entered Continuous Program Step Successfully

Single Flash

ON

Short Single Beep

Entered Program Step Incorrectly

ON

3 Short Beeps

Exited from Program Mode

Flashing

Short Single Beep

Entry Granted

ON

Short Single Beep

Alarm Mode Engaged

Flashing

Alarm

Pressing ✱ Toggles Standby/Master Code Entry

ON/Flashing

Short Single Beep

Sound & Light Indication

Programming Step

Keystroke Combination

To reset the door forced
open warning

(Read valid card)

OR

(Master Code #)

To reset the door open too
long (DOTL) warning

(Read valid card)

OR

(Master Code) #

ANTI-TAMPER ALARM

The KPR2000 uses an optical sensor as the input for its internal alarm. If
the case is opened while the KPR2000 is powered, the alarm will operate.
To silence, enter a valid credential or cycle power.

© 2012, The Chamberlain Group Inc.

01-36716B All

Rights

Reserved

FOR TECHNICAL SUPPORT DIAL OUR TOLL FREE NUMBER:

1-800-528-2806

Erase all Codes

This will delete ALL User data.

1. Enter Program Mode by pressing: ✱ (Master Code) #.

2. Press 2 0000 #.

All configuration data is retained.

ADVANCED PROGRAMMING

TO RESET THE ALARM