1 how to set a counter – Teledyne LeCroy Summit T24 PCIe Multi-lane Protocol Analyzer User Manual User Manual

Page 94

Advertising
background image

Teledyne LeCroy

Counter

82

Summit T24 PCI Express Multi‐Lane Protocol Analyzer User Manual

Note:

It is an invalid configuration for some events when you try and set a counter and timer 

when both channels are selected.

The counters have different colors for the Global State and Sequence State. Each color 
signifies a different meaning in the Global and Sequence states (see 

Figure 5.40 on 

page 82

).

Note:

Global timers/counters can be used by events from any direction as long as the events occur 

more than 380 ns apart. State timer/counters can be controlled only from one direction not 
both, meaning starting, reset and incrementing must be done from events occurring in the same 
direction of the selected timer/counter.

Figure 5.40: Global and Sequence State Counters

As shown in 

Figure 5.40

 there is a Global Counter 1, set to the value of 2 on channel up 

displayed in green in the Global State and there are two counter 1s, set to the value of 2, 
one counting upstream and the other counting downstream displayed in pink in the 
Sequence State.

5.22.1 How to Set a Counter

Counters are events and you can add a counter to the Global State or the Sequence State 
as an event by doing the following:

Advertising