Number of errors, Protocol error type – Teledyne LeCroy TA660СА User Manual

Page 127

Advertising
background image

TA660 User's Manual

Catalyst Enterprises, Inc

121

Number of Errors

Detected errors are displayed as an ERROR signal name in red in the
display window if the signal ERROR has been selected for display on
the screen.

To determine the total number of errors encountered in the entire
captured data file click Tools on the analyzer menu bar and then
select Number of Errors to open the number of errors display
box as shown in Figure 109.

Figure 109 Number of Errors Display

Protocol Error Type

To view the type of the detected protocol error in either a list or wave
display you must make sure that the ERROR signal has been added to
the display. Figure 110 illustrates a typical protocol error wave
display with the ERROR signal added. The error appears as a red
number on the error signal line where it occurred in synch with the
rest of the PCI bus signals. To determine the protocol error type
triggered on, double click on the red NUMBER to open the detected
protocol error message shown in Figure 111.

The check mark(s) next to the error(s) indicate(s) the type of the
error(s) and description of the error according to PCI specifications.